Procedure
l
Press
INFO
key again to display 4-20 mA calibration figures.
15.1.9.4 Analog Scaling Factor
Scaling Factor adjusts 4-20 mA profile using a multiplication factor.
To select Analog 4-20 mA mode:
Procedure
1. Press
+/-
from
HOME
screen to access scaling factor
2. Use
+/-
keys to enter multiplication factor:
l
1.00 will not alter 4-20 mA profile
l
2 will double flow rate output from mA signal
l
0.5 will halve the output
15 INSTALLATION: PART 6 (SETTING UP THE PUMP (CONTROL SETTINGS))
144