It is possible to install different pumpheads on some drive models, except the Remote model, in accordance with
this table:
Drive
Standard pump
configuration
Alternative pumphead which may be fitted to
the drive
Drive
Pumphead
Maximum pressure
Pumphead
Maximum pressure
qdos 20
ReNu 20 SEBS
7 Bar / 100 psi
CWT 30 EPDM
7 Bar / 100 psi
ReNu 20 PU
4 Bar / 60 psi
qdos 30
ReNu 30 SEBS
7 Bar / 100 psi
ReNu 30
Santoprene
4 Bar / 60 psi
qdos 60
ReNu 60
Santoprene
7 Bar / 100 psi
ReNu 60 SEBS
4 Bar / 60 psi
ReNu 60 PU
5 Bar / 70 psi
qdos 120
ReNu 120
Santoprene
4 Bar / 60 psi
ReNu 60
Santoprene
7 Bar / 100 psi
ReNu 60 SEBS 60 4 Bar / 60 psi
ReNu 60 PU
5 Bar / 70 psi
qdos CWT
CWT 30 EPDM
7 Bar / 100 psi
ReNu 20 SEBS
7 Bar / 100 psi
NOTE4
It is only possible to purchase a complete pump as a
standard pump
configuration.
NOTE5
All pressures stated in these instructions are Root Mean Squared (RMS) gauge pressures