Configuration Settings
Name
Name
Description
Description
Default
Default
Level
Level
92 PRES LOW
Configures the discharge pressure threshold under which the discharge pressure will turn on the PRESSURE
DROPPED alarm. Range is 30 to 250 PSI, adjustable in 5 PSI steps.
30 PSI
OEM
93 LOW HYDRANT Configures the LOW HYDRANT alarm. Range is ENABLED, DISABLED.
DISABLED
OEM
94 INT. P-THRES
Configures the intake pressure threshold. Range is 0 to 50 PSI, adjustable in 5 PSI steps.
40 PSI
Service
95 INT. PRES L
Configures the intake pressure threshold under which the intake pressure will turn on the LOW HYDRANT
PRESSURE alarm. Range is 5 to 40 PSI, adjustable in 5 PSI steps.
20 PSI
Service
96 INT. TIMEOUT
Configures delay (in seconds). Range is 0 to 120, adjustable in 5 second steps.
0
Service