Configuration Settings
Name
Name
Description
Description
Default
Default
Level
Level
1 UNITS
Displayed units of measure in PSI/°F, kPa/°C, MPa/°C, or bar/°C.
PSI/F
User
2 PRESET RPM
Preset button speed in RPM when in speed mode. Choose from: 900 to 1500 RPM in increments of 25.
1000
User
3 PRESET PSI
Preset button pressure when in pressure mode. Choose from: 90 to 130 PSI in increments of 10.
90
User
4 HIGH IDLE
Engine speed in RPM when in high idle mode. Choose from: 900 to 1400 RPM in 25 RPM steps.
1100
User
5 SENSITIVITY
Engine speed is not adjusted until difference between set-point and actual pressure in PSI is greater than the
sensitivity value. Choose from: 2 to 10 PSI.
5
User
6 RPM GAIN
Change in engine speed in RPM for each button press of knob detent. Choose from: 1 to 30.
15
User
7 PRESS GAIN
Change in pump pressure in PSI for each button press or knob detent. Choose from: 1 to 10.
5
User
8 ALLOW
PRESET
Enable or disable operation of speed mode preset button when pump pressure is greater than 10 PSI.
Choose: yes or no.
No
User
9 SMOOTHING
Number of samples used in the averaging of the pressure sensor measurement. Choose: from no, low, or high.
No
User
10 PSET MIN
Minimum pump discharge pressure in PSI before the preset button will operate in pressure mode. Choose
from: 0 to 100 PSI in increments of 5.
25
User
11 NUDGE LIMIT
Engine speed is not adjusted until difference between speed set-point and actual engine speed is greater than
the nudge limit value. Choose from: 0 to 25 RPM in increments of 5.
15
User
12 LAG DELTA PSI Engine speed is not adjusted until the difference between pressure set-point and actual pressure is greater
than the lag delta PSI value. Choose from: 1 to 5 PSI.
1
User
13 ROUNDING
Enable or disable rounding of the pressure or speed displays. Choose from: no, PSI, RPM, or both.
No
User
14 IDLE RPM
Idle mode engine speed in RPM. Choose from: 600 to 900 RPM in increments of 25.
Note:
The speed must
be greater than the engines curb idle speed.
No
User
15 PSI TIME-OUT
Number of seconds that the pressure can be below 30 PSI in pressure mode. Choose from: 3 to 10 seconds.
3
User
16 DISCHARGE
SENSOR
Discharge sensor full scale pressure. Choose from: 300 or 600 PSI.
Note:
Set the value to 300 PSI for a
single-stage pump, and 600 PSI for a two-stage pump.
300
User
17 INTAKE
SENSOR
Intake sensor full scale pressure. Choose: 300 or 600 PSI.
300
Service
18 DIS. 0 CAL
Calibrates the discharge sensor 0 PSI value. Press the preset button with discharge at 0 PSI to run the
calibration.
—
Service