Configuration Settings
Name
Name
Description
Description
Default
Default
Level
Level
75 PRESS LIMIT
Configures the maximum allowed pressure increase when in RPM mode. Choose from: 10 to 100 PSI in
increments of 5.
30
Service
76 RPM LIMIT
Configures the minimum change in pressure expected (when in pressure mode) for an increase of 200 RPM in
engine speed. Range is 5 to 100 RPM, adjustable in 5 RPM steps.
10
Service
77 RPM TIMEOUT
Configures delay (in seconds) between “RPM LIMIT” detection and the application of the restriction/limit of
set-point in pressure mode. Range is 0 to 30 seconds, adjustable in 1 second steps.
1
Service
78 H20 TIMEOUT
Configures delay (in seconds) between “PRESSURE DROPPED” detection and the application of the
restriction/limit of set-point in RPM mode. Range is 5 to 120 seconds, adjustable in 5 second steps.
10
Service
79 DECEL RATE
Configures RPM deceleration rate to IDLE preset. Range is 200 to 2000 RPM, adjustable in 100 RPM steps.
500
Service
80 COM STATUS
Displays the CAN bus engine speed message count or number of errors.
NA
Service
81 COMPANY
Configures the OBD to J1939 gateway protocol (typically used only in Ford chassis). Options currently
available are NONE, 1939CM405A, 1939XR501A, 1939CM506AP, and 1939CM550AP.
Innovative
OEM
82 OBD to J1939
Configures the OBD to J1939 gateway protocol (typically used only in Ford chassis). Options currently
available are NONE, 1939CM405A, 1939XR501A, 1939CM506AP, and 1939CM550AP.
None
OEM
83 FUEL LOW
Configures the fuel percentage at which the FUEL LOW alarm is set. Range is 0% to 100%, adjustable in 5%
steps.
15 %
Service
84 DEF LOW
Configures the DEF percentage at which the DEF LOW alarm is set. Range is 0% to 100%, adjustable in 5%
steps.
15 %
Service
85 Control Mode
Configures the control modes allowed for use. Options are “PSI & RPM”, “PSI ONLY”, and “RPM ONLY”.
PSI & RPM
OEM
86 P-TIME
Configures sample rate in milliseconds (ms) for analog pressure control mode. Range is 10ms to 1000ms,
adjustable in 10ms steps.
500 ms
OEM
87 S-TIME
Configures sample rate in milliseconds (ms) for analog speed control mode. Range is 10ms to 1000ms,
adjustable in 10ms steps.
500 ms
OEM
88 WARN. TRANS
Configures the temperature above which the transmission oil temperature will turn on the transmission
warning (yellow) lamp. Range is 140°F to 260°F, adjustable in 10°F steps.
230°F
OEM
89 CRIT. TRANS
Configures the temperature above which the transmission oil temperature will turn on the transmission critical
(red) lamp. Range is 140°F to 260°F, adjustable in 10°F steps.
250°F
OEM
90 DIS. P-THRES
Configures the discharge pressure threshold under which the discharge pressure will turn on the NO WATER
alarm. Range is 15 to 250 PSI, adjustable in 5 PSI steps.
15 PSI
OEM
91 PRES HIGH
Configures the minimum discharge pressure required before a “PRESSURE DROPPED” alarm message is
possible. Range is 50 to 250 PSI, adjustable in 5 PSI steps.
50 PSI
OEM