38
|
53
Configuring the Pressure Governor—OEM Configuration Mode
1
2
3
4
5
6
Use the illustration and instructions to open the
OEM configuration mode, change parameters, and
exit the configuration mode. Configure the pressure
governor with the appropriate parameters for your
application. For a description of the parameters in
this mode, refer to:
The OEM configuration mode gives you access to
the all settings. Follow the instructions below to
access the OEM configuration mode.
1 From ready mode, press and hold the
Idle
or
Status
button while entering the password
sequence as shown.
2 The RPM display shows P and the selected
parameter number when in the configuration
mode.
3 Use the
PSI
and
RPM
buttons to change the
parameter number.
4 Use the
+
and
–
buttons or the
Rotary Knob
to
change the parameter value.
5 Press the
Preset
button to store the parameter
value.
6 Press the
Idle
or
Status
button to exit the
configuration mode.