30
|
53
Installing the Pressure Sensors
1
2
Use the illustration and instructions to install the
intake and discharge-pressure sensors.
You can improve the accuracy of the sensors by
calibrating them at 0 pressure. You can also
calibrate a second set-point using a static pressure
source. Refer to:
to configure the 0 and
static set-points.
1 To install the intake-pressure sensor, do the
following:
•
Install the intake-pressure sensor to the
water-pump intake.
•
Make sure that the intake-pressure sensor is
set to 300 PSI. Refer to:
Pressure Governor—User Configuration
parameter 17.
2 To install the discharge-pressure sensor, do the
following:
•
Install the discharge-pressure sensor to the
water-pump discharge.
•
Make sure that the discharge-pressure sensor
is set to 300 PSI for a single-stage pump, and
600 PSI for a two-stage pump. Refer to:
"Configuring the Pressure Governor—
User Configuration Mode" on page 35
parameter 16.