Configuration Settings
Name
Name
Description
Description
Default
Default
Level
Level
19 INT. 0 CAL
Calibrates the intake sensor 0 PSI value. Press the preset button with intake at 0 PSI to run calibration.
—
Service
20 DIS. OFFSET
Calibrates the discharge sensor at a known pressure. Use the +/– buttons or knob controls to set the menu to
the applied pressure. Press the preset button to run the calibration.
Note:
The static pressure calibration point
must be within 20% of the full sensor value.
—
Service
21 INT. OFFSET
Calibrates the discharge sensor at a known pressure. Use the +/– buttons or knob controls to set the menu to
the applied pressure. Press the preset button to run the calibration. Press the preset button to run the
calibration.
Note:
The static pressure calibration point must be within 20% of the full sensor value.
—
Service
22 ENGINE TYPE
Engine control type. Choose from: Cummins FPG, J1939 PGN0, Scania, Volvo, Mercedes, or, analog.
Cummins
OEM
23 BRIGHTNESS
Adjusts display brightness. Automatic adjusts the brightness depending on ambient light conditions. Choose
from: 1 to 10 manual setting or automatic.
Automatic
User
24 DISPLAY TEST
Turns on all front panel LED indicators and display pixels for 2 seconds. Press the preset button to start the
display test.
—
User
25 ALERT TONE
Enables or disables the double beep alert tone. Choose: yes or no.
Yes
User
26 DISPLAY
Changes the numerical display to either RPM mode or a pressure set-point. Choose: RPM or PSI SET.
RPM
Service
27 VOLT OFFSETS Offset that is applied to the battery voltage display. Choose from: –0.5 to 0.5 VDC in increments of 0.1.
0.0
Service
28 KNOB INC
DIRECTION
Adjusts which knob direction causes an increase. Choose: CW or CCW.
CW
User
29 COM STATUS
Displays the CAN bus engine speed message count or number of errors.
—
Service
30 BAUD RATE
Adjusts the CAN bus engine control speed. Choose from: 250K, 500K or automatic.
500K
Service
31 FACTORY
DEFAULT
Returns all of the configuration parameters to their factory defaults. Press the preset button to set all
parameters to default.
—
Service
32 ENGINE ID
Configures the CAN bus source address of the engine. Choose from: 0 to 255.
0
OEM
33 DAY
Sets the real-time-clock day of the month. Choose from: 1 to 31.
1
User
34 MONTH
Sets the real-time-clock month of the year. Choose from: 1 to 12.
1
User
35 YEAR
Sets the real-time-clock year. Choose from: 2000 to 3000.
2018
User
36 HOUR
Sets the real-time-clock hour of the day. Choose from: 0 to 23.
0
User
37 MINUTE
Sets the real-time-clock minute of the hour. Choose from: 0 to 59.
0
User
38 PUMP HOURS
Changes the pump hours value. Use the +/– buttons or knob controls to adjust the pump hours setting. Press
the preset button to run the calibration.
0
Service