INTELLIZONE2 INSTALLATION MANUAL
Blower Data - Package Unit cont.
5 Series - Single Speed with Variable Speed ECM
Model
Max ESP
Blower Speed Settings with IntelliZone2 Blower Level Percentages
1
2
3
4
5
6
7
8
9
10
11
12
036
0.50
650
750
850
G
1000
1100
L 55%
1200
70%-85%
1300
H 100%
1400
1500
1550
Aux
036
w/1hp*
0.75
800
1000
G
1100
L 55%-70%
1300
H 85%-100%
1500
1600
1800
1950
2100
2200
Aux
042
0.50
650
800
900
G
1050
1150
L 55%
1250
70%
1350
85%
1450
H 100%
1550
1600
Aux
042
w/1hp*
0.75
800
900
G
1000
1200
L 55%-70%
1400
H 85%-100%
1600
1700
1850
2000
2200
Aux
2300
2400
048
0.50
650
800
900
1050
G
1150
1250
1350
L 55%
1450
70%-85%
1550
H 100%
1600
Aux
048
w/1hp*
0.75
800
900
1000
G
1200
1400
L 55%-70%
1600
H 85%-100%
1700
1850
2000
2200
Aux
2300
2400
060
0.75
800
950
1100
G
1300
1500
L 55%
1750
70%-85%
1950
H 100%
2100
2300
2325
Aux
070
0.75
800
950
1100
G
1300
1500
1750
L 55%
1950
70%-85%
2100
H 100%
2300
2325
Aux
Blower level percentages are shown with factory recommended blower speed settings
Factory settings are at recommended G-L-H-Aux speed settings
L-H settings MUST be located within boldface CFM range
“Aux” is factory setting for auxiliary heat and must be equal to or above the “H” setting as well as at least the minimum required for the auxiliary heat package
“G” may be located anywhere within the airflow table
CFM is controlled within 5% up to the maximum ESP
Max ESP includes allowance for wet coil and standard filter
6/8/12
7 Series - Variable Speed with Variable Speed ECM
Model
Max ESP
7 Series Blower Speed Settings with IntelliZone2 Blower Level Percentages
Speed 1
Speed 2
Speed 3
Speed 4
Speed 5
Speed 6
Speed 7
Speed 8
Speed 9
Speed 10
Speed 11
Speed 12
036
0.50
285
380
G
525
L 25%
675
40%
815
980
55%
1100
70%
1220
1330
85%
1440
H 100%
1540
Aux
1575
036 w/1hp*
0.75
480
565
G
665
L 25%
761
40%
870
1000
55%
1100
70%
1200
1300
85%
1410
H 100%
1520
Aux
1630
048
0.75
475
620
G
730
L 25%
850
40%
1020
1140
55%
1270
70%
1400
1520
85%
1650
H 100%
1790
Aux
1925
060
0.75
400
600
G
830
L 25%
1050
40%
1230
1400
55%
1560
70%
1700
1870
85%
2010
H 100%
2140
Aux
2265
**VS Compressor
Speed
1-2
3-4
5-6
7-8
9-10
11-12
Blower level percentages are shown with factory recommended blower speed settings
** VS Compressor speed is given for the factory default cfm settings. When the cfm default settings are changed it will change the relationship to the compressor
speed that is shown in the table. In cooling mode compressor speeds 10-12 are only available when SuperBoost mode is selected at the thermostat.
* optional 1 HP ECM
Factory speed settings are at recommended G, L , H and Aux positions
“G” may be located anywhere within the airflow table
“L” setting should be located within the boldface CFM range
“H” setting MUST be located within the shaded CFM range
“Aux” setting MUST be equal to or greater than the minimum allowable CFM for the auxiliary heater kit (see auxiliary heat ratings table)
CFM is controlled within 5% up to the maximum ESP
Max ESP includes allowance for wet coil and standard filter
6/7/12
5 Series - Dual Capacity with Variable Speed ECM
MODEL
MAX ESP
AIR FLOW SPEED SETTINGS
1
2
3
4
5
6
7
8
9
10
11
12
026
0.50
400
G
500
600
L 55%
700
70%
800
85%
900
H 100%
1000
1100
1200
Aux
038
0.50
650
750
G
850
L 55%
1000
70%
1100
1200
85%
1300
H 100%
1400
1500
1550
Aux
038 w/1hp*
0.75
800
G L 55%
1000
70%
1100
85%
1300
H 100%
1500
1600
1800
1875
1925
2000
Aux
049
0.50
650
800
G
900
1050
L 55%
1150
1250
70%
1350
85%
1450
1550
H 100%
1575
Aux
049 w/1hp*
0.75
800
900
G
1000
L 55%
1200
70%
1400
85%
1600
H 100%
1700
1850
2000
2200
Aux
2300
2400
064
0.75
800
950
G
1100
L 55%
1300
70%
1500
85%
1750
H 100%
1950
2100
2300
2325
Aux
072
0.75
800
950
1100
G
1300
L 55%
1500
70%
1750
85%
1950
H 100%
2100
2300
2325
Aux
10/5/12
Factory settings are at recommended G-L-H-Aux speed settings
L-H settings MUST be located within boldface CFM range
“Aux” is factory setting for auxiliary heat and must be equal to or above the “H” setting as well as at least the minimum required for the auxiliary heat package
“G” may be located anywhere within the airflow table
CFM is controlled within ±5% up to the maximum ESP
Max ESP includes allowance for wet coil and standard filter