Error Code
Description of the Error
Malfunction
Probable Cause
Solution(s)
E 94
Possible low gas pressure
or exhaust recirculation
Boiler does not work, E94
error code flashing on the
screen
> Gas inlet pressure LOW
> Recirculation on fluegas
path
> Blokage on flue or wrong
flue
> Aging or rust on the
electrode
> Electrode position
> Combustion calibration
> Gas valve failiure
> Electronic board
1-) Call for authorised service at first
2-) Check wrong flue OR flue gas blockage
3-) Check recirculation ( flue gas leak ) from flue gas path to fresh air
side, check flue gas sealings specially
4-) Check any problems on the ionisation electrode, (like
condensation, rust etc.), and control poistioning of the electrode, if
electrode poistion wrong calibrate the electrode.
5-) Check combustion CO or O values on HI and LO mode at
sweeper mode.
6-) Perform Auto Calibration.
7-) if not successfull replace gas valve, and Perform Au-To calibration.
8-) If fault still persists Replace board, but use original service key
from the board dismantled to keep original parameters and calibration
points. If original service key not used aslo adjust P15 releated to the
default value of boiler power and perform Au-To calibration.
Attention: Only authorised service must perform Au-To calibration
E 95
Intermittent combustion
value
Boiler does not work, E95
error code flashing on the
screen
> Harness on electrode
and earth
> Aging or rust on the
electrode
> Electrode position
> Combustion calibration
1-) Call for authorised service at first
2-) Check intermittent contacts on harness carefully
3-) Check any problems on the ionisation electrode, (like
condensation, rust etc.), and control poistioning of the electrode, if
electrode poistion wrong calibrate the electrode.
4-) Check for condensation on the cabling AND/OR on board
5-) Check earth connection between board and electrode
6-) Check electrode cabeling between board and electrode
7-) Check combustion CO or O values on HI and LO mode at
sweeper mode.
8-) Perform Au-To calibration.
Attention: Only authorised service must perform Au-To calibration
E 96
Flue or air suction way
blockage
Boiler does not work, E96
error code flashing on the
screen
> Blokage on flue
> Blokage on air suction
path
1-) Call for authorised service at first
2-) Check wrong flue OR flue gas blockage
3-) Check recirculation ( flue gas leak ) from flue gas path to fresh air
side, check flue gas sealings specially
4-) Check venturi inlet if its blocked
5-) Check any blockage between fan and burner
6-) Check combustion CO or O values on HI and LO mode at
sweeper mode.
7-) Perform Auto Calibration.
Attention: Only authorised service must perform Au-To calibration
E 98
SW error, board start-up
error fault
Boiler does not work, E98
error code flashing on the
screen
> Boiler software problem
1-) Call for authorised service at first
2-) Replace board direcly, adjust P15 releated to the default value of
boiler power
3-) Perform Au-To calibration.
Attention: Only authorised service must perform Au-To calibration
E 99
Generic fault
Boiler does not work, E99
error code flashing on the
screen
> Boiler electronic
hardware problem
1-) Call for authorised service at first
2-) Replace board direcly, adjust P15 releated to the default value of
boiler power
3-) Perform Au-To calibration.
4-) if not successfull replace gas valve, and perform Au-To calibration.
Attention: Only authorised service must perform Au-To calibration
flashing
LCD
Half Power mode on Lawa
/ Lawa Plus models
Boiler continue to work,
flashing screen boiler still
operational
> Recirculation on fluegas
path
> Blokage on flue or wrong
flue
> Combustion calibration
> Temporary wind
precence
1-) If there is strong wind (ie.wind storm) wait until the wind storm
stop then keep using the boiler as it is 36 or 48 hours boiler try to
remove half power mode by it self automatically by increasing power
gradually.
2-) IF problem persist after 48 hours Call for authorised service
3-) Check wrong flue OR flue gas blockage
4-) Check recirculation ( flue gas leak ) from flue gas path to fresh air
side, check flue gas sealings specially
5-) Activate service man menu and dis activate to remove half power
mode
6-) IF problem still persist then perform Auto Calibration
Attention: Only authorised service must perform Au-To calibration
Содержание EWA 2525C
Страница 1: ...CONDENSING COMBI BOILERS INSTALLATION SERVICE MANUAL EWA 2525C 25 kW EWA 2530C 30 kW...
Страница 2: ......
Страница 3: ...3 warmhaus co uk...
Страница 28: ...28 warmhaus co uk 3 16 Ewa Combi Boiler Wiring Diagram Wiring Diagram RISK OF ELECTRIC SHOCK 0100_00 W211130...
Страница 57: ...57 warmhaus co uk...