20
warmhaus.co.uk
3.11. Installation with Vertical Flue Sets
(Ø60/100 mm)
Your Warmhaus boiler can also be installed with a vertical flue system that
can terminate on both flat and pitched roofs, vertical flue installations must
not exceed 11 m in total.
Apply a suitable lubricant to the sealing joints before connecting any flue
products and ensure the vertical flue terminal is installed level without a
slope.
The vertical flue terminal can be fitted to both flat and pitched surfaces.
Flue Data
WARNING
Warmhaus flue pipe technical specification:
Vertical Termination:
• Maximum length = 11 meters including the bend or adaptor connected
directly to the boiler.
•
Elbow
Equivalent To Straight Length
45 Degree
0.5 meter
90 Degree
1.0 meter
Ø60/100mm, L max = 11m
A
INFORMATION:
The vertical flue terminal can be fitted to both flat
and pitched surfaces.
0043_01.W210420
0044_
0
1.W21
07
07
0045_00.D181122
Содержание EWA 2525C
Страница 1: ...CONDENSING COMBI BOILERS INSTALLATION SERVICE MANUAL EWA 2525C 25 kW EWA 2530C 30 kW...
Страница 2: ......
Страница 3: ...3 warmhaus co uk...
Страница 28: ...28 warmhaus co uk 3 16 Ewa Combi Boiler Wiring Diagram Wiring Diagram RISK OF ELECTRIC SHOCK 0100_00 W211130...
Страница 57: ...57 warmhaus co uk...