45
warmhaus.co.uk
4.5. Information Menu Access
Info Menu
Designation:
Ewa Combi Boiler wall-hung boilers
Object
Type-model / Technical data
Mark (s) of conformity
Procedure Info Menu
Ewa Combi Boiler
granted by Warmhaus R&D
Pos No Operation
Description GB
0
Attention:
This procedure must be applied by authorised persons.
1
To enter the INFO menu, Push two button RESET + "DHW" simultaneously.
2
Wait until the approval circle complete on the LCD and release buttons.
3
Now you are in the "Info" menu. Toggle the values by pressing "+" OR "-" buttons. You can not change the values
displayed in the "info" menu. From this moment by toggle MODE you can check following Informations: Last 10
Failure ( Error ) codes - Information by reading some real values – Counters Menu
4
From AL 0 to AL9 show last 10 Error code that boiler had previously. Error code shown after the AL code (ie. When
you see AL0 on the screen wait 1-2 sec the error code will shown like E06.)
5
INFO MENU = In X value shows following information
6
In0 = SW version
In1 = Display of external probe temperature, if connected,C°
In2 = Display of CH Flow probe temperature, C°
In3 = Display of Safety Limit probe temperature – Display flue probe temperature, C°
In4 = Display of DHW probe temperature, C°
In5 = Display of CH Return probe temperature, C°
In6 = Display of real heating temperature SET, C°
In7 = Display of actual power level, %
In8 = Display of Flow-meter actual value, Lt/ per-minute
In9 = Display of water pressure value ( on PLUS models ONLY ), Bars
In10 = Actual Fan Speed RPMx100
COUNTER MENU = Co X value shows following information
7
Co0 = Display of main supply hours, hx100
Co1 = Display of burner total functioning hours, hx100
Co2 = Display of burner total ignitions, x1000
Co3 = Display of total failures shown on the boiler, x1
Co4 = Display of number of TSP menu activation, x1
Co5 = Display of number of OEM menu activation, x1
Co6 = -
the LCD and release button. İn this way Alarm history will be ereased.
8
To Exit the menu
Push two button MODE + RESET simultaneously
9
Wait until the approval circle complete on the LCD and release buttons. In this way EXIT the info menu.