33
warmhaus.co.uk
Transparent Parameters Menu (TSP)
Designation :
All Warmhaus Wallhung Boilers
Object
Type-model(s)
Burner Control Transparent Parameter List
Ewa Combi Boiler
Parameter no.
Parameter
Value Field
Ewa 2525C
Default
Ewa 2530C
Default
P01(*)
Hydraulic system
0 – 3
0
0
0 = Instantaneous
1 = Thermostat storage tank
2 = NTC Storage tank
3 = Heating Only
P02
Gas type
0 – 1
"0 = NG
1 = LPG"
"0 = NG
1 = LPG"
0 = Natural gas
1 = LPG
P03
DHW inlet configuration
0 – 2
2
2
0 = Flow switch
1 = Flow meter
2 = Flow meter AND W/O DHW Sensor Algorithm
P04
4 - 90
30
30
P05
Anti fast cycles time ( value 1 = 1 minute )
0 - 10 min
3
3
P06
Maximum CH power
0 % - 100 %
N/A
N/A
P07
Ignition heating ramp time (value 1 = 10 seconds)
0 - 80
60
60
P08
Maximum CH power
P10 - 100 %
80
80
P09
Maximum DHW power
P10 - 100 %
82
100
P10
Minimum power
0 % - P09
0
0
P11
CH Minimum temperature setpoint value ( °C )
20 °C - P12
25
25
P12
CH Maximum temperature setpoint value ( °C )
P11 - 85 °C
80
80
P13
DHW maximum temperature setpoint value ( °C )
35 °C - 65 °C
60
60
P14
Type of calibration
0 - 20
0
0
0 = Manuel calibration / ma - nu
5 = Auto calibration / Au - To
P15
Boiler Power Output
0 - 8
6
6
0
1 = 28 kw
2 = 33 kw
3 = 50 kw
4 = 65kw
5 = 24n kw - New Burner
6 = 24E kw ( D02 HEAT EXCHANGER )
7 = 28E kw ( D02 HEAT EXCHANGER )
8 = 33E kw ( D02 HEAT EXCHANGER )
CALIBRATION MUST BE CARRIED OUT IF P15 IS CHANGED!
4.1.2. Parameters
(*) For conversion from combi boiler to system boiler change the parameter P1=0 to P1=3
Содержание EWA 2525C
Страница 1: ...CONDENSING COMBI BOILERS INSTALLATION SERVICE MANUAL EWA 2525C 25 kW EWA 2530C 30 kW...
Страница 2: ......
Страница 3: ...3 warmhaus co uk...
Страница 28: ...28 warmhaus co uk 3 16 Ewa Combi Boiler Wiring Diagram Wiring Diagram RISK OF ELECTRIC SHOCK 0100_00 W211130...
Страница 57: ...57 warmhaus co uk...