The combustion pot is located on the inside of the combustion door and can be removed for
servicing and routine maintenance by releasing the toggle latches on either side of the pot as
shown in Figure 2. Once the toggle latches are released the pot will be free to lift vertically from
the combustion shelf.
Caution: never attempt to remove the pot after the appliance has
just finished operating as it will be extremely hot and injury will result.
The ash level in the ash pan should be checked periodically. The ash pan must never be
permitted to over fill. Under normal operating conditions during the heating season the ash pan
will typically require emptying on a monthly basis. The appliance should never be operated
without the ash pan in position. The ash may be discarded with garden waste or in line with
local waste disposal regulations, after first ensuring that it is sufficiently cool before emptying
the pan.
Caution: never attempt to remove the ash pan after the appliance has just
finished operating as it will be extremely hot and injury will result.
The combustion pot should be cleaned on a weekly basis removing any carbon residue.
Vacuuming with a dedicated ash vacuum cleaner is recommended. Failure to clean the
combustion pot as directed may restrict the flow of air within the appliance adversely affecting
its performance.
Figure 2: Combustion Door and Ash Pan Assembly.
Ash pan
Combustion pot
Toggle latch
Inspection Door
Содержание WS18
Страница 85: ...84 INTENTIONALLY LEFT BLANK...
Страница 97: ...96 9 APPENDIX A SUPPLEMENTARY INSTALLATION AND OPERATING INSTRUCTIONS FOR THE UK MARKET...
Страница 105: ...104 10 APPENDIX B CUSTOMER CONNECTION WIRING SCHEMATIC...
Страница 106: ...105...