28
•
Lift the combustion door handle up while still holding the door release button as shown in
Figure 37 “Lift UP”.
•
The combustion door can now be opened and the door release button can be released.
Leave the combustion door handle fully up until STEP 16.
•
The “Combustion door OPEN” alarm will be activated on the user control interface when
the combustion door is opened. Do not attempt to clear this alarm whilst the cleaning
procedure is in progress. The “Combustion door OPEN” alarm will clear automatically
when all steps of this cleaning procedure are complete.
STEP 6 – Clean the Combustion Shelf
•
Use a suitable brush* to remove any build-up of ash/dust off the combustion shelf with
the combustion pot still in place. (* A dedicated ash vacuum cleaner may also be used.
Make sure the ash is sufficiently cool before vacuuming.)
STEP 7 – Remove the Combustion Pot
•
Unfasten the two toggle latches on either side of the combustion pot (See Figure 39).
•
Lift the combustion pot vertically upwards away from the cleaning knives (See Figure 39).
•
Set the combustion pot to the side ensuring that if hot, it is not placed in contact with
materials that may be affected by heat.
Figure 38: Combustion Shelf
Combustion
shelf
Combustion
pot