73
Alarm Screen
Possible Cause(s)
Suggested Action(s)
Action By
User
Engineer
The clear 6mm ID hoses connected to the
pressure sensor, combustion door and
exhaust fan outlet are disconnected or
damaged.
The pressure sensor is faulty or
disconnected.
Ensure the clear 6mm ID hoses are not
damaged and are connected to the correct
ports on the pressure sensor. Replace hoses if
necessary.
Test the operation of the pressure sensor and
re-connect/replace if necessary.
ü
ü
Blockage in 6mm ID hose connected to the
pressure sensor.
Blockage on connector at exhaust fan or
combustion door
Remove blockage or replace blocked hose
ü
Table 16: Alarms Schedule 5