62
Text
Default value
Description
Fuel Alarm
(mins)
60 mins
This is the amount of appliance firing time in minutes allowed after a low fuel
level has been triggered in order to prevent the appliance from running out of
pellets in the auger feed mechanism.
Auger Mode
Variable
The built-in fuel regulation function of the appliance will automatically select
the correct auger mode. The appliance monitors the intake fan speed when
specific operating conditions have been satisfied and makes adjustments to
the auger mode to ensure the fan speed remains within tolerance of a pre-set
target. Auger mode range = 0 - 26
Table 10: Description of Engineer Parameters Screen 3
Text
Default value
Description
Unit Serial No. 00000000
This is where the appliance serial number marked on the label on the inside of
the front door is entered into the user control interface. Each character of the
serial number is entered individually using the ‘Up Arrow’ key and
‘Down
Arrow’ key, and then the ‘Enter key’ to advance to the next character.
It is important to enter the serial number of the appliance to provide both local
and remote identification for the appliance.
Table 11: Description of Engineer Parameters Screen 4
Figure 84: Engineer Parameters Screen 3
Figure 85: Engineer Parameters Screen 4