![WarmFlow WS18 Скачать руководство пользователя страница 41](http://html2.mh-extra.com/html/warmflow/ws18/ws18_manual_3559733041.webp)
40
Your local authority is responsible for implementing the Clean Air Act 1993 including
designation and supervision of smoke control areas and you can contact them for details of
Clean Air Act requirements.
The installation must comply with regional Building Regulations. The maximum noise level
generated by the appliance is well within the residential noise limitations and is similar to that of
a high efficiency oil boiler.
The appliance is secured on a wooden pallet for shipping. The appliance is fixed to this pallet
using five screw fasteners through its base. Remove these screw fasteners before attempting to
remove the appliance from the pallet. The screw fasteners can be accessed by opening the
front casing door and both removable side panels (See Figure 58).
3.2 General Requirements
3.2.1 Transportation aids and hearth
The appliance can be supplied with an optional WPTRK WP Install Buggy comprising of an
axle, 2 wheels, support strap and fasteners.
This optional WP install buggy must only be used on solid level surfaces.
Details on how to assemble these items are below:
•
Remove and retain the 1x grommet located along each lower side edge of the appliance.
•
Insert the axle through the now exposed holes.
•
Secure 1 wheel to each side of the boiler with the supplied washers on each side of each
wheel.
•
Insert the supplied R clips on each end of the axle to secure the wheels.
•
Remove and retain the grommet from the lower edge rear of the appliance.
•
Secure the support strap with the supplied bolt and washer.
The wheels and support strap can now be used to guide the appliance into the required
location.
Stand clear, and exercise caution following current manual handling regulations, as the
appliance has a dry weight of 250kg.
Once the appliance has been placed correctly, remove WP install buggy, and replace the
grommets.
The appliance has a hearth temperature of between 50°C and 85°C and should be placed on a
level, rigid, non-porous, non-combustible base, which is not softened by heat, to comply with
current local Building Regulations. Please refer to table 1 for product mass data.
Ground fixings may be used if required – locations for securing the appliance to the shipping
pallet can be used for this purpose. Ensure opening of the combustion door is not impeded by
any fixings used.