3.7.5 CT (Current Transducer) or ammeter connected to inverter
In the system, a CT (Current Transducer) or electricity meter must be installed to monitor the
electrical energy consumption of the house and the state of the inverter (charging or discharging).
The CT or ammeter should be installed at the grid input terminal to enable the inverter to monitor
the household’s overall electricity consumption.
Based on the CT readings, the inverter can adjust the PV power delivered to the grid to maintain a
balance between the household's energy usage and generation level (see Figure 20).
Using a lithium battery that is compatible and has been tested with the inverter is
recommended. Make sure the communication is normal.