The maximum open-circuit voltage of each group of PV input should not be higher than 500V
DC.
Please check the design of the PV plant carefully to ensure compliance with this specification.
When the ambient temperature of the PV panel is -10°C, the maximum open circuit voltage may
appear, and the input voltage at this time must not exceed the maximum input voltage of the
inverter (500V).
3.7.3 PV panel connections (Refer to Figure 16 and Figure 17)
This device supports two PV access, refer to Figure 17.
1. There is a risk of electric shock and fire. The maximum input voltage
per string should not exceed 500V DC.
2. There is no transformer design, and the positive and negative ends are not grounded.
WYIN5K