19 Technical data
51
100_0102_td_0006.fm
The following points must be observed:
Only use permitted extension cables.
Refer to nameplate for details of type designation and voltage of this machine.
Refer to the following table for the required cross-section area.
Machine type
Voltage
[V]
Extension
[m] (ft)
Cross-section area of
cable
[mm
2
]
AR63/6/250
250 3~
< 150 (492.1)
1,5
AR64/1,5/400
400 3~
< 150 (492.1)
1,5
AR64/3/230
230 3~
< 150 (492.1)
1,5
AR64/3/400
400 3~
< 150 (492.1)
1,5
AR64/6/042
42 3~
< 15 (49.2)
4
< 22 (72.2)
6
< 34 (111.5)
10
AR64/6/250
250 3~
< 150 (492.1)
1,5
AR64/9/042
42 3~
< 20 (65.6)
4
< 30 (98.4)
6
< 47 (154.2)
10
Machine type
Voltage
[V]
Extension
[m] (ft)
Cross-section area of
cable
[AWG]
AR63/6/250
250 3~
< 150 (492.1)
16
AR64/1,5/400
400 3~
< 150 (492.1)
16
AR64/3/230
230 3~
< 150 (492.1)
16
AR64/3/400
400 3~
< 150 (492.1)
16
AR64/6/042
42 3~
< 12 (39.4)
12
< 19 (62.3)
10
AR64/6/250
250 3~
< 150 (492.1)
16
AR64/9/042
42 3~
< 11 (36.1)
14
< 17 (55.8)
12
< 26 (85.3)