19 Technical data
49
100_0102_td_0006.fm
19.2
AR64
Designation
Unit
AR64/1,5/400
AR64/3/230
AR64/3/400
AR64/6/042
Item no.
5100004207
5100004024
5100004210
5100004216
Rated current
A
1,40
3,00
1,70
21,50
Rated voltage
V
400
230
400
42
Rated frequency
Hz
50
50
50
200
Rated output
kW
0,80
0,90
0,90
1,20
Phases
~
3
3
3
3
Centrifugal force
kN
3,98
9,27
9,27
10,36
Vibrations
rpm
1,500
3,000
3,000
6,000
Hz
25
50
50
100
Centrifugal force max.
kN
5,05
16,05
16,05
19,03
Length
mm (in)
352 (13.9)
352 (13.9)
352 (13.9)
245 (9.6)
Width
mm (in)
150 (5.9)
150 (5.9)
150 (5.9)
150 (5.9)
Height
mm (in)
188 (7.4)
188 (7.4)
188 (7.4)
188 (7.4)
Weight
kg (lb)
21.00 (46.3)
18.69 (41.2)
18.69 (41.2)
13.80 (30.4)
Motor type
Induction motor
Class rating
l
l
l
lll
Protection class *
IP65
IP65
IP65
IP65
Storage temperature range
°C (°F)
-30 – +70
(-22 – +158)
-30 – +70
(-22 – +158)
-30 – +70
(-22 – +158)
-30 – +70
(-22 – +158)
Operating temperature
range
°C (°F)
-10 – +50
(+14 – +122)
-10 – +50
(+14 – +122)
-10 – +50
(+14 – +122)
-10 – +50
(+14 – +122)
Housing external
temperature
°C (°F)
80 (176)
80 (176)
80 (176)
80 (176)
Sound pressure level L
pA
**
dB(A)
76
76
76
76
Standard
EN ISO 11201, EN 12649
*
Only guaranteed with a Wacker Neuson power cable.
**
Measured at distance of 1 m (3.2 ft).