10 Use and operation
100_0102_op_0003.fm
26
10.4
Electrical connection
10.4.1
Connecting to a generator
Starting the generator:
1. Unplug all plugs from the generator.
2. Start the generator - see the generator operator's manual.
3. Allow the generator to warm up for approx. 3 minutes.
4. Check that the ON/OFF switch on the machine is switched off.
5. On machines without an ON/OFF switch, check that the inverter is switched off.
6. Plug the power cable into a free plug receptacle of the generator.
7. Use an additional extension cable if necessary.
10.4.2
Connecting to mains power
1. Check that the ON/OFF switch on the machine is switched off.
2. On machines without an ON/OFF switch, check that the inverter is switched off.
3. Plug the power cable into a free plug receptacle on the generator.
4. Use an additional extension cable if necessary.
Note ARFU
Perform the following function tests:
1. Push the test button on the Bodyguard®.
The indicator light turns off when the protection through the Bodyguard® is operational.The mains
side power supply is cut off.
The indicator light doesn't turn off if a fault exists in the Bodyguard®, see chapter Faults.
2. Pull plug out of plug receptacle.
3. Reconnect the machine to the power supply.
10.5
Switching on the machine
Before the installed machine is switched on with the ON/OFF switch, the following points must be
observed and checked:
Check that the machine is securely positioned in the fastening clamp/formwork.
Check safety belt for firm seating.
No persons must be in the immediate vicinity of the machine.
The control lamp (if there is one) comes on when the machine is supplied with voltage.
CAUTION
Improper handling can cause damage.
Unplug other electrical devices from the generator before switching on the machine.
The remaining power output from the generator must not be exceeded for the
connection of additional electrical devices.
NOTE
The indicator light on the Bodyguard® illuminates red when the machine is ready for
operation.
NOTE
15 - 20 minutes after switching on, switch off external vibrators and retighten all fastening