9 Installation
100_0102_is_0003.fm
22
Installation – cable to terminal board box
Compliance with the following steps is required when installing the cable to the terminal board
box:
1. Connect power cable as shown in wiring diagram.
2. Fit grounded conductor (only for machines of protection class rating I).
3. Fastening the seal and lid -Seal must sit correctly.
4. Terminal board box must be dust-free and dry when sealed. Tighten the screws on the lid of the
terminal board box - The screws are glued in and tightened with 3.5 Nm.
9.2.2
AR5, 6, 7 Installation – power cable
Compliance with the following steps is required when installing the power cable:
1. Unscrew the screws from the terminal box.
2. Remove the cover, seal, and molded rubber part.
3. Guide the power cable through the cable gland, cable support sleeve, and terminal box hole - Torque
7.5 Nm.
4. Screw the cable gland to the terminal box - Torque 3.0 Nm.
NOTE
When attaching two external vibrators, ensure that they rotate in opposite directions.
Item
Description
Item
Description
1
Screws
4
Molded rubber part
2
Cover
5
Cable gland
3
Seal