Group 30: Electrical system
Diagnostic Trouble Codes
123
Fault tracing
FMI 3 Abnormally high voltage or short
circuit to higher voltage
Possible reason:
•
Short circuit to battery voltage in sense wire.
•
Heating element broken.
Suitable action:
1.
Check cable harness and connectors to heating
element.
2.
Check function of preheat relay.
3.
Change heating element.
FMI 4 Abnormally low voltage or short
circuit to lower voltage
Possible reason:
•
Short circuit to battery negative in sense wire.
Suitable action:
1.
Check function of preheat relay.
2.
Check cable harness and connectors to heating
element.
FMI 5
Possible reason:
•
An open circuit in sense wiring.
•
Heating element broken.
Suitable action:
1.
Check contact pressure in socket 7 in engine con-
nector B.
2.
Check cable harness and connections to heating
element.
3.
Change heating element.
Содержание TAD650VE
Страница 1: ...Workshop Manual Group 30 TAD650VE TAD660VE TAD734GE TAD750VE TAD760VE I 4 0 ...
Страница 2: ......
Страница 150: ...Wiring diagram Group 30 Electrical system 148 EMS 2 engine harness TAD734 GE ...
Страница 157: ...155 References to Service Bulletins Group No Date Refers to Group 30 Electrical system References to Service Bulletins ...
Страница 158: ...Notes ...
Страница 160: ...7747632 English 03 2007 ...