Diagnostic Trouble Codes
Group 30: Electrical system
130
Fault tracing
FMI 3 Abnormally high voltage or short
circuit to higher voltage
Conditions for fault code:
The voltage exceeds the normal value or is short cir-
cuited to higher voltage.
Possible reason:
•
Short circuit between 5V supply voltage and bat-
tery voltage in EMS 2 connector A.
Suitable action:
1.
Check all 5V supply cables distributed by EMS 2
connector A. (see EMS 2 wiring diagram)
FMI 4 Abnormally low voltage or short
circuit to lower voltage
Possible reason:
•
Short circuit between the supply cables to the
boost pressure sensor.
•
Short circuit between the supply cables to the rail
pressure sensor.
Suitable action:
1.
Check the sensor supply cables to boost pressure
sensor.
2.
Check the sensor supply cables to rail pressure
sensor.
Содержание TAD650VE
Страница 1: ...Workshop Manual Group 30 TAD650VE TAD660VE TAD734GE TAD750VE TAD760VE I 4 0 ...
Страница 2: ......
Страница 150: ...Wiring diagram Group 30 Electrical system 148 EMS 2 engine harness TAD734 GE ...
Страница 157: ...155 References to Service Bulletins Group No Date Refers to Group 30 Electrical system References to Service Bulletins ...
Страница 158: ...Notes ...
Страница 160: ...7747632 English 03 2007 ...