Group 30: Electrical system
Diagnostic Trouble Codes
51
Component specification
Working range: 0 – 7 bar = 0 – 700 kPa
Supply voltage: 5,00 +/- 0,25 VDC
Nominal output voltage at 25 °C and at supply voltage
5,00 VDC:
0,5 VDC at 0 bar = 0 kPa
4,5 VDC at 7 bar = 700 kPa
Checking the oil pressure sensor
•
NOTE!
Turn ignition off.
•
Disconnect the connector from the sensor
•
Connect adapter cable 885675 between the sen-
sor and the engine control unit.
•
Use multimeter 9812519 for voltage measurement
•
Turn ignition on.
Measurement points
Nominal value
2 – 3
U
≈
0,5 V (at normal
atmospheric pres-
sure)
Output voltage, V
Oil pressure, kPa
Содержание TAD650VE
Страница 1: ...Workshop Manual Group 30 TAD650VE TAD660VE TAD734GE TAD750VE TAD760VE I 4 0 ...
Страница 2: ......
Страница 150: ...Wiring diagram Group 30 Electrical system 148 EMS 2 engine harness TAD734 GE ...
Страница 157: ...155 References to Service Bulletins Group No Date Refers to Group 30 Electrical system References to Service Bulletins ...
Страница 158: ...Notes ...