Group 30: Electrical system
Diagnostic Trouble Codes
97
MID 128 / 144, PPID 132
Throttle input request failure, DCU/CIU
MID 128: Engine control unit
MID 144: Control interface unit
FMI 3: The voltage exceeds the normal value or is
short circuited to higher voltage.
FMI 4: The voltage is less than the normal value or
is short circuited to battery negative.
FMI 9: Abnormal update rate
FMI
Fault code explanation
3, 4
Faulty throttle potentiometer /
Faulty throttle potentiometer circuit
9
EMS2 is missing the throttle signal
Fault indication
DCU:
Engine warning in DCU display.
CIU:
Flashcode
Flash code
Electrical fault: 2.8
Value fault:
None
Symptom
Engine goes to idle. If the accelerator is released at
first and then pressed down again the engine can be
forced to run using the idle contact.