Group 30: Electrical system
Diagnostic Trouble Codes
117
FMI 5
Conditions for fault code:
Open circuit.
Possible reason:
•
An open circuit in starter relay cable.
•
Faulty starter relay.
Suitable action:
1.
Check cable harness and connections between
starter relay and EMS 2.
2.
Check contact pressure in socket B29 in engine
connector.
3.
Check function of starter relay.
Measurements
Checking starter relay coil
1.
NOTE!
Cut the current with the main switch.
2.
Remove one of the wires to the starter relay.
3.
Use multimeter 9812519 to measure the resis-
tance in the coil.
Measurement points
Nominal value
Relay connectors
R
≈
9 – 15
Ω
Checking starter relay voltage supply
1.
Turn ignition off.
2.
Connect multimeter 9812519 to do a voltage mea-
surement over the starter relay.
3.
Turn ignition on.
Measurement points
Nominal value
Relay connectors
V
≈
0 V
4.
Push start button.
Measurement points
Nominal value
Relay connectors
V
≈
Battery Voltage