Group 30: Electrical system
Diagnostic Trouble Codes
71
Checking coolant temperature
sensor
•
NOTE!
Cut the current with the main switch.
•
Connect adapter cable 885675 to the sensor.
Do
not
connect the other end of the adapter ca-
ble.
•
Use multimeter 9812519 to do resistance mea-
surement.
Measurement points
Nominal value
1 – 2
R
≈
9397
Ω
+/- 755
Ω
(at -10° C )
1 – 2
R
≈
5896
Ω
+/- 430
Ω
(at 0° C )
1 – 2
R
≈
2500
Ω
+/- 148
Ω
(at 20° C )
1 – 2
R
≈
1175
Ω
+/- 56
Ω
(at 40° C )
1 – 2
R
≈
596
Ω
+/- 22
Ω
(at 60° C )
1 – 2
R
≈
323
Ω
+/- 10
Ω
(at 80° C )
1 – 2
R
≈
186
Ω
+/- 5
Ω
(at 100° C )
1 – 2
R
≈
113
Ω
+/- 4
Ω
(at 120° C )