Diagnostic Trouble Codes
Group 30: Electrical system
36
FMI 5 Abnormally low current or open
circuit
Possible reason:
•
An open circuit in cable harness between EMS 2
and preheat relay.
Suitable action:
1.
Check the contact pressure in socket 25 in the
engine connector B.
2.
Check cable harness and connectors between
EMS 2 and preheat relay.
Measurements
NOTE!
If any of the measurements shows an abnor-
mal value, check the wiring to and from the engine
control unit and the preheat relay.
Checking the wiring:
1. NOTE!
Cut the current with the main switch.
2.
Remove connector B from the EMS 2.
3.
Connect the B connector to brakeout cable
9990014 with measurebox 9998699.
4.
Use multimeter 9812519 to do a resistance mea-
surement.
Measurement points on box Nominal value
7 (preheat sense) -
R
≈
0
Ω
one of the preheat connectors
25 (relay activation) -
R
≈
0
Ω
one of the preheat connectors
60 (relay +) -
R
≈
0
Ω
one of the preheat connectors