Engine room, ventilation and sound proofing
76
Insulation material applied on GRP:
. GRP
2. Iron-PVC, thickness 2.5 mm (0.")
3. Flame-proof absorption sheeting
4. Flame-proof, reflecting soundproofing foil
Prior to installing the insulation material, make sure
that there is sufficient room for checking, service and
repair and for the engine movements during opera-
tion.
Above you can see an example of the build-up of an
insulation sheeting. This type of insulation material is
glued to the frame.
NOTE! The insulation sheeting is turned differently,
owing to the type of the material in the frame, i.e.
GRP or wood.
Insulation material, being applied on wood (plywood):
. Wood (plywood)
2. Flame-proof absorption sheeting.
3. Flame-proof, reflecting soundproofing foil.
Make sure the necessary room is available for serv-
ice and repair. Also make sure that all hatches are
properly sealed off.
Greatest possible care must be given to the task
of screening the sound source as well as possible.
Screen all the way down to the hull but leave a small
distance to prevent bilgewater from penetrating insu-
lation material.
Cracks, openings etc. must be carefully sealed off
with insulation material. In cases where the engine
is installed under the floor, dress all bulkheads and
floorboards.