Cooling system
88
Coolant flow and connections
for engines adapted for exter-
nal cooling
Engines adapted for external cooling differ from sea-
water cooled engines. The seawater pump and the
heat exchanger(s) have been removed. The engines
have been fitted with connections for the external
cooling system.
The figures below show the connections on the en-
gines and the inner diameter of the hoses.
D5/D7
One circuit keel cooling
. To keel cooler
2. From keel cooler
2.
∅
50 mm (2")
.
∅
50 mm (2")