Electrical system
53
External stop relay
D12D-A MP
The auxiliary stop can be controlled remotely by installing two relays in series with the auxiliary stop wiring.
The function can be used for a third party fire extinguishing system. Please contact Volvo Penta for further infor-
mation.
D9/D11/D12D-B MP/D16
The D9, D, D2D-B MP, and D6 engines are equipped with a relay that can be remotely controlled by third
party equipment, e.g. a fire extinguishing system. The engine shuts down when the relay is energized.
NOTE! Leave the external stop connector unconnected if the functionality is not to be used.
Fault codes presented on Vodia when external stop
relay is activated (D9, D, D2D-B MP and D6):
MID128, PPID 6, FMI 11
Connecting the external stop relay
• Locate the two-pole connector on the right hand
side of the engine.
• Connect the accessory cable kit.