Getting ready for operation
US edition 2021/01
VH / VTS / VBL / VAI Translation of the original operating manual
Subject to change without notice
23
Contact:
+49(0)92 78-774 33-0
+49(0)92 78-774 33-11
www.vogt-tec.com
4. Connect the VTS’s compressed air supply hose to the pneumatic con-
trol.
5�3 Supplying compressed air to the VH and VTS
The compressed air supply (e.g. from a compressor) must fulfill the follow-
ing criteria:
Only use lubricated, condensate-free compressed air. Use accessories
to pre-treat the compressed air if required, such as the VOGT precision
in-line oiler Z 300.
Working pressure range: 3 to 6 bar (44 to 87 psi).
An effective feed rate of at least:
−
190 l/min. for the following models: VH 25 / VH 25 Delta / VH 30 /
VH 30 Delta
−
255 l/min for the following models: VH 50 / VH 50 Delta / VH 50.18
/ VH50.18 Delta / VH 60 / VH 60 Delta / VH 60.18 / VH 60.18 Delta /
VTS 50 / VTS 60
−
This generally equates to a minimum suction capacity of around
380-450 l/min. for compressors.
Note:
To connect the VOGT compressed air device to the compressed air
supply (e.g. compressor), you will need an air intake hose with an inside
diameter of at least 9 mm, such as a VOGT metal hose drum (Z 100) or VOGT
compressed air hose (Z 110). Use a hose with a larger cross-section if cover-
ing distances of over 30 m. Compressed air hoses with a claw coupling must
be fitted with an adapter – e.g. a VOGT adapter from 3/4" to a standard con-
nection (Z 200) – at the end at which the VOGT compressed air device is to be
connected. This is to be done while the device is still depressurized.
Connecting the compressed air supply
Follow these steps to connect your VOGT compressed air device to the
compressed air supply:
Risk of damage to rammer and tools�
Danger of device and tool damage.
¾
Check the pressure of the compressed air supply and
adjust it to max. 6 bar.
¾
Use an additional pressure gauge if required
(VOGT pressure gauge Z 400).
Содержание VH 25