Safe use
US edition 2021/01
VH / VTS / VBL / VAI Translation of the original operating manual
Subject to change without notice
31
Contact:
+49(0)92 78-774 33-0
+49(0)92 78-774 33-11
www.vogt-tec.com
Note:
One top-up of oil should be used up within two to three days of
work. If the recommended consumption differs significantly, turn the ad-
justment screw 1/8 of a turn in the corresponding direction and continue
to monitor the oil consumption.
Testing the adjusted
quantity of oil
Follow these steps to test the adjusted quantity of oil:
1. Operate the compressed air device for around ten minutes at a time.
2. Disconnect the compressed air device from the compressed air sup-
ply.
3. Remove the tool that you were using and look closely at the tool hold-
er and tool:
−
If the end of the tool that is inserted (hexagon) is coated lightly with
oil or black after use, the oiler is set correctly.
−
If the end of the tool that is inserted is metallic and shiny, the oil
quantity is set too low.
−
If the oil is leaking from the valve on the handle or along the chisel,
the oil quantity is set too high.
4. If necessary, readjust the quantity of oil on the in-line oiler.
Oil types
Please use VOGT Special Oil (Z 500) or a resin-free pneumatic oil when
working in standard conditions.
On request, VOGT can supply the following oils for non-standard condi-
tions of use:
High-temperature oil (832 010) for particularly high ambient tempera-
tures.
Low-temperature oil (835 010) for particularly low ambient tempera-
tures.
Bio-oil (834 010) for working in food-processing plants or similar envi-
ronments.
Material safety data sheets for the various VOGT oils available can be
found in the downloads area of the VOGT website.
Содержание VH 25
Страница 2: ... 2 ...