3
System
description
Vista SmartDisc 10IP
19
3.7 Pin assignment and functionality
General
All
terminals
are
pluggable.
It
is
recommended
to
remove
the
screw
type
terminal
for
wiring,
especially
of
the
terminal
block.
This
makes
wiring
of
incoming
and
outgoing
lines
more
convenient.
The
screw
type
terminals
are
grouped
by
functionality.
34 pin terminal block
Pin
Labelling/
description
Type
Function
1
RS-485–
Serial
(D–)
Use
this
terminal
to
connect
up
to
10
remote
control
cameras
or
other
compatible
devices
(e.g.
matrix)
with
RS-485/RS-422
interfaces.
2
RS-485+
Serial
(D+)
3
Ground
Common
ground
for
RS-232
interface
4
RS-232
Tx
Serial
TxD
Use
this
terminal
to
connect
1
remote
control
camera
or
one
other
compatible
device
(e.g.
matrix)
with
RS-232
interface.
5
RS-232
Rx
Serial
RxD
6
Ground
Common
ground
for
all
inputs
of
type
"control
input"
7
Al
a/d
Control
input
Arm/Disarm
input
for
enabling/disabling
dial-up
to
a
SmartControl
receiver
PC,
controlled
by
"Control
in",
"Al
in",
and
"Motion
Detection".
8
Aux
in3
Control
input
Auxiliary
input
3:
Reserved
9
Al
in
Control
input
Alarm
input
for
dial-up
with
automatic
switching
of
video
input
1
(V1
in)
to
a
SmartControl
receiver
unit.
Note: The operation of this input always depends on the status of arm/
disarm input "Al a/d"
10
Aux
in1
Control
input
Tamper
input
for
dial-up
with
automatic
switching
of
video
input
1
(V1
in)
to
a
SmartControl
receiver
unit.
Note: The operation of this input is independent of the status of the
arm/disarm enable input "Al a/d"
11
to
15
Control
in
1-5
Control
input
Camera
control
inputs
for
external
contact
triggered
recording
and/or
selective
dial-up
to
a
SmartControl
receiver
unit
for
video
inputs
1
to
5.
These
control
inputs
can
be
used
for
event
recording
as
well
as
for
event
optimised
permanent
long-term
recording.
16
Ground
Common
ground
for
all
inputs
of
type
"control
input"
17
Ground
Common
ground
for
all
inputs
of
type
"control
input"
18
12V
DC
+
Power,
+
Supply
voltage
is
nominal
12V
DC
(Voltage
input
from
8-16
V
DC).
Only
connect
the
device
to
your
local
power
supply
system
using
the
provided
power
supply
unit
with
the
prepared
connection
cable.
Only
use
the
power
supply
cable
matching
your
grid
(Euro/UK).
19
12V
DC
Power,
ground
⊥
⊥
⊥
⊥
⊥
Содержание SmartDisc 10IP
Страница 2: ...SmartDisc 10IP English Version 1 84 Device Manual ...
Страница 3: ......
Страница 4: ...Vista SmartDisc 10IP 3 Vista SmartDisc 10IP Device Manual ...
Страница 9: ...1 How to use this manual 8 Vista SmartDisc 10IP ...
Страница 39: ...4 Commissioning 38 Vista SmartDisc 10IP ...
Страница 57: ...6 Web Server 56 Vista SmartDisc 10IP ...
Страница 61: ...7 SmartDisc 10IP Technical Data 60 Vista SmartDisc 10IP ...
Страница 73: ...11 Supplement 72 Vista SmartDisc 10IP ...