Option and default
Configuration Instructions
46:PSTN RETRIES
4 attempts
Define the number of times the system will retry to report to the Monitoring Station in case of
failure to report via the PSTN telephone line connection.
Options:
2 attempts
;
4 attempts
;
8 attempts
;
12 attempts
and
16 attempts
.
47:GSM RETRIES
4 attempts
Define the number of times the system will retry to report to the Monitoring Station in case of
failure to report via the cellular connection - GPRS (IP), GSM and SMS.
Options:
2 attempts
;
4 attempts
;
8 attempts
;
12 attempts
and
16 attempts
.
48:BB IP RETRIES
4 attempts
Define the number of times the system will retry to report to the Monitoring Station in case of
failure to report via the Broadband Module connection.
Options:
2 attempts
;
4 attempts
;
8 attempts
;
12 attempts
and
16 attempts
.
51:TEL AUTO TEST
Test OFF
To verify a proper communication channel, the PowerMaster can be configured to send a test
event to the Monitoring Station via PSTN periodically. You can set the interval between the
consecutive test events or disable the automatic sending of this event entirely. If the interval is
set for every one day or more then the exact hour of reporting can be selected with option 52.
Options:
test OFF
;
every 1
/
2
/
5
/
7
/
14
/
30 day(s)
; and
every 5 hours
.
52:AUTO TST TIME
12:00
Enter the exact time (
auto test time
) during the day at which the Auto Test message (if enabled
in option 51) will be sent to the Monitoring Station.
Note:
If the AM/PM format is used, you can set the "AM" and the "PM" digits using the numbers
on the keypad
.
53:COM.FAIL RPRT
Determine whether a failure in any of the system communication channels i.e. PSTN,
GSM/GPRS, or Broadband will be reported or not and the time delay between detection of the
failure and reporting of the failure event to the Monitoring Station. A trouble event (i.e. "tel line
fail", "GSM line fail” or “broadband fail") will be respectively stored in the event log.
PSTN FAIL
immediate rprt
GSM GPRS FAIL
do not report
BROADBAND FAIL
(Return)
Previously known as
"LINE FAIL REPORT"
Options "
PSTN FAIL
":
immediate rprt
;
after 5
/
30
/
60
/
180 min
and
rprt disabled
.
Options "
GSM GPRS FAIL
":
after 2
/
5
/
15
/
30 min
and
do not report
.
Options "
BROADBAND FAIL
"
after 1/2/5/15/30 min, 1/3/6 hours
and
do not report
(default).
61:RPRT CNF ALRM
rprt disabled
Define whether the system will report whenever 2 or more events (confirmed alarm) occur
during a specific period or enable the report and bypass the detector.
46
D-306919 KP-250 PG2 Installer’s Guide