Zone No. and Type
Description
Zxx: ZONE TYPE
7. Perim-Access
(Perim-follow)
Similar to "Perimeter" zone, but is temporarily ignored by the alarm system
during entry/exit delay periods. Usually used for sensors protecting the route
between the entrance door and the control panel.
Zxx: ZONE TYPE
8. 24h silent
This zone type is active 24 hours, even when system is DISARMED. It is used
to report alarm events from sensors or manually activated buttons to the
monitoring station or private telephones (as programmed) without activating the
sirens.
Zxx: ZONE TYPE
9. 24h audible
Similar to 24hr silent zone, but also provides an audible siren alarm.
Zxx: ZONE TYPE
10. Emergency
This zone type is active 24 hours, even when the system is DISARMED. It is
used to report an emergency event and to initiate an
Emergency call
to the
monitoring stations or private telephones (as programmed).
Zxx: ZONE TYPE
11. Arming Key
An Arming key zone is used to control the arming and disarming of the system
by an external wired system or simple key switch connected to the panel's wired
zone input or a wired input of a PowerG device.
Note:
If the wired input of the panel or PowerG device is closed, the control panel
will be armed. If it is opened, the control panel will be disarmed - refer to the
PowerMaster-10/30 G2 Installer’s Guide, Figure 3.6b (PowerMaster-10 G2) /
Figure 4.9b (PowerMaster-30 G2), or, PowerMaster-33 G2 Installer’s Guide,
Figure 3.8b.
Zxx: ZONE TYPE
12. Non-Alarm
This zone does not create an alarm and is often used for non-alarm
applications. For example, a detector used only for sounding a chime.
Zxx: ZONE TYPE
13. Fire
A Fire zone is used for connecting the MC-302E (magnetic contact with hard-
wired input) to a wired smoke detector.
Zxx: ZONE TYPE
17. Guard keybox
Note:
Depending on the
configuration this option may
not be available.
A Guard keybox zone is usually connected to a metal safe containing the
physical keys needed to enter the building. Following an alarm, the safe
becomes available to a trusted Guard who can open the Guard keybox, obtain
the keys and enter the secured premises. The Guard keybox zone acts just like
a 24H audible zone. The Guard keybox zone also provides automatic audible
internal sounder and external siren alarm that is immediately reported to the
Monitoring Station (and does not depend on the Abort Time).
Note:
Opening/closing the Guard keybox causes the PowerMaster to signal the
Monitoring Station.
Zxx: ZONE TYPE
18. Outdoor
A zone for outdoor areas where an activated alarm does not indicate intrusion
into the house. This zone type generates an alarm when the system is armed
both in AWAY and HOME modes. Events are sent to private phones and not to
the Monitoring Station.
Zxx: ZONE TYPE
19. Int./Delay
This zone type behaves as an “Interior” zone when the system is armed ‘Home’
and as a “Delayed” zone when the system is armed ‘Away’.
Zxx: ZONE TYPE
20. Tamper
This is a 24 hour zone operating all of the time even when the system is
disarmed. The tamper zone reports tamper alarm events from an external wired
device.
The behavior is the same as opening the tamper switch of a detector.
18
D-306919 KP-250 PG2 Installer’s Guide