3.5.5 Configuring Sirens Functionality
The following table provides you with a detailed description of each option and its configuration settings. To select an
option and change its configuration – refer to section 3.5.1.
Option and default
Configuration Instructions
43:PANEL SIREN
on
Determine whether the control panel’s built-in siren will sound alarms – “
on
” or remain
silent – “
off
”.
Options:
on
and
off
.
44:SIREN TIME
4 minutes
Define the period of time the sirens will sound upon alarm.
Previously known as "BELL
TIME"
Options:
1
/
90 seconds
/
3
/
4
/
8
/
10
/
15
/
20 minute(s)
.
Note:
To comply with
EN
requirements, the "Siren Time" must not exceed
15 minutes.
45:STROBE TIME
20 minutes
Define the length of time the strobe light will flash upon alarm.
Options:
5
/
10
/
20
/
40
/
60 minutes
.
46:SIREN ON LINE
disable on fail
Determine if the siren will be activated when the phone line fails and the system is
armed.
Options:
disable on fail
or
enable on fail
.
32