Option and default
Configuration Instructions
Options:
disabled
;
cellular, broadband
and
PSTN
.
Important:
Only selected communication channels will be used by the system to report event messages to
Monitoring Stations.
If none is selected, the reporting to monitoring stations will be
disabled
.
Note:
When
Cellular
channel is selected, the order of priority will be GPRS (IP) channel
first, then GSM voice channel and lastly SMS channel, provided that these channels have
been enabled (see section 3.6.3).
05:DUAL RPRT
disable
Define whether or not to report events using PSTN and broadband, PSTN and cellular or
broadband and cellular communication channels.
Options:
disable
;
PSTN&broadband
;
PSTN&cellular
and
broadband&cell
.
11:RCVR1
ACCOUNT
001234
Enter the respective 1
st
Account (subscriber) number (11:RCVR 1 ACCOUNT) that will identify
your specific alarm system to the 1
st
Monitoring Station (designated as RCVR1 or RCV1) and a
2
nd
Account (subscriber) number (12:RCVR 2 ACCOUNT) that will identify the system to the 2
nd
Monitoring Station (designated as RCVR2 or RCV2). Each of the Account numbers consists of 6
hexadecimal digits.
12:RCVR2
ACCOUNT
005678
Master Installer only
To enter Hexadecimal digits, use the following table:
Entering Hexadecimal Digits
Digit
0…..9
A
B
C
Keying
0…..9
[#]
[0]
[#]
[1]
[#]
[2]
Digit
D
E
F
Keying
[#]
[3]
[#]
[4]
[#]
[5]
16:PSTN/GSM RCV1
The PowerMaster can be programmed to report the event messages defined in the Report
Events option (option 01) to two Alarm Format Receivers via PSTN telephone line and/or GSM
analog voice channel (if equipped with GSM module), using standard PSTN alarm formats (i.e.
SIA, Contact-ID and Scancom). The reporting format is defined in the "PSTN Report Format"
option (option 41).
Enter the two respective telephone numbers (
including area code
– maximum 16 digits) of the
Alarm Format Receiver 1 located at the 1
st
Monitoring Station (16: PSTN/GSM RCV1) and alarm
format Receiver 2 located at the 2
nd
Monitoring Station (17: PSTN/GSM RCV2).
17:PSTN/GSM RCV2
Master Installer only
Note:
If any of the phone numbers programmed herein contain an
area code
identical to the area
code of the PSTN telephone line to which the system is connected, you should refer to the "
AREA
CODE
" option in section 3.6.2.and act as instructed there.
Digit Keying Digit Significance
A
[#]
[0]
The dialer waits 10 seconds or waits for a dial tone, whichever comes first
and then dials. Applicable only at the 1
st
digit.
D
[#]
[3]
The dialer waits 5 seconds for a dial tone and goes on hook if none is
received. Applicable only at the 1
st
digit.
E
[#]
[4]
The dialer waits 5 seconds. Applicable only in the middle of the number.
44