149
Rated heating output range
at T
F
/T
R
50/30 °C
kW
3.2 (4.8)
*2
- 13
3.2 (4.8)
*2
- 19
5.2 (8.8)
*2
- 26
at T
F
/T
R
80/60 °C
kW
2.9 (4.3)
*2
- 11.8
2.9 (4.3)
*2
- 17.2
4.7 (8.0)
*2
- 23.7
for DHW heating
kW
2.9 (4.3)
*2
- 17.2
2.9 (4.3)
*2
- 17.2
4.7 (8.0)
*2
- 29.3
Rated heating input range
kW
3.1 (4.5)
*2
- 17.9
3.1 (4.5)
*2
- 17.9
4.9 (8.3)
*2
- 30.5
Supply values
relative to the max. load
Natural gas E
m
3
/h
1.89
1.89
3.23
Natural gas LL
m
3
/h
2.20
2.20
3.75
LPG P
kg/h
1.40
1.40
2.38
Power consumption
In the delivered condition
W
39
53
68
Maximum
W
157
160
209
Rated voltage
230 V
Rated frequency
50 Hz
Rated current
6 A
Protection class
I
IP rating
IP X 4 to EN 60529
Permissible ambient temperature
■
During operation
0 to +40 °C
■
During storage and transport
–
20 to +65 °C
Electronic temperature limiter setting
82 °C
Temperature limiter setting
100 °C (fixed)
Backup fuse (power supply)
max. 16 A
Product ID
_
-0085CN0050
Note
The connection values are only for reference (e.g. in
the gas contract application) or for a supplementary,
rough estimate to check the volumetric settings. Due to
factory settings, the gas pressure must not be altered
from these values. Reference: 15 °C, 1013 mbar
(101.3 kPa).
*2
Only when operating with LPG P
Specification
Specification
5773 238 GB
Appendix
Содержание 7513244
Страница 11: ...11 8 9 4x 8x 12 10 11 Fig 2 Preparing for installation Installation preparations cont 5773 238 GB Installation ...
Страница 12: ...12 13 14 15 Fig 3 Preparing for installation Installation preparations cont 5773 238 GB Installation ...
Страница 13: ...13 16 Fig 4 Preparing for installation Installation preparations cont 5773 238 GB Installation ...
Страница 14: ...14 sF 17 19 21 20 18 Fig 5 Preparing for installation Installation preparations cont 5773 238 GB Installation ...
Страница 15: ...15 24 22 23 Fig 6 Preparing for installation Installation preparations cont 5773 238 GB Installation ...
Страница 16: ...16 27 26 25 Fig 7 Preparing for installation Installation preparations cont 5773 238 GB Installation ...
Страница 35: ...35 2x 1 4 2 3 5 Fig 27 Installation sequence Fitting the front panels 5773 238 GB Installation ...
Страница 135: ...135 Parts lists Hydraulic assembly 5773 238 GB Components ...
Страница 146: ...146 0004 0002 0005 0006 0001 0003 Fig 107 Parts lists Miscellaneous 5773 238 GB Components ...