Indoor Pendant Model
The indoor pendant model mounts on a Vicon mount (refer to the table in the Introduction section) or a 1.5-
inch vertical pipe with an appropriate coupling. The pipe is a standard 1.5-inch NPT type and must be
oriented vertically so the SurveyorVFT can effectively hang from the pipe.
Indoor Pendant Overview
The mount is installed with all the cables run through it or the 1.5-inch NPT pipe is prepared for SurveyorVFT
installation. The cables are routed through the housing and the housing is screwed tightly to the pipe. Then
the customer interface board is wired. The SurveyorVFT camera drive is hung from the housing safety cord.
The SurveyorVFT drive is then carefully snapped into the housing. The SurveyorVFT is supported by the
mount. The indoor lower dome is snapped on. Refer to Figure 11. Detailed installation instructions follow.
The accessory kit contains the removable terminal blocks for all connections in this installation. The mount
must provide a support of suitable strength for the indoor pendant SurveyorVFT weight of 4.7 lb (2.1 kg).
1. Install the mount in accordance with the
installation manual included with the mount or
prepare the vertical 1.5-inch NPT pipe.
Figure 11
Indoor Pendant Mount Model
2. Feed all necessary cables through the back of the
mount or out the end of the 1.5-inch NPT pipe.
3. Unlatch and rotate the customer interface board
90º downward to provide access to the terminal
blocks. Refer to Figure 12. (The board can be
completely removed if necessary by snapping it
out of the hinge after being rotated to the 90º
downward position.)
5. Lift the housing up to the mount or pipe and feed
the cables through its top opening.
6. Place the housing onto the pipe and screw
clockwise, looking up at the housing. When snug,
turn an additional quarter-turn.
7. Remove the terminal blocks provided in the
accessory kit. The 2-pin is for power, the two (2)
8-pin are for alarms and control/relay; the 3-pin is
for UTP option. Terminate all the cables as
follows:
a) Strip approximately 1 inch (25 mm) of the
cable outer jacket to be terminated in terminal
blocks TB1 and TB3. Then strip approximately
0.25 inches (6 mm) of insulation off of each
individual wire.
XX134-07-00 Rev 908 SurveyorVFT Camera Dome System
4BInstallation
•
19
Содержание SVFT-C22
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 15: ...Unpacking the SurveyorVFT Outdoor Pendant XX134 07 00 Rev 908 SurveyorVFT Camera Dome System 3BIntroduction 7...
Страница 18: ...10 3BIntroduction XX134 07 00 Rev 908 SurveyorVFT Camera Dome System...
Страница 33: ...Figure 18 Outdoor Lower Dome Installation XX134 07 00 Rev 908 SurveyorVFT Camera Dome System 4BInstallation 25...
Страница 34: ...26 4BInstallation XX134 07 00 Rev 908 SurveyorVFT Camera Dome System NOTES...
Страница 36: ...Figure 19 Customer Interface Board Connections 28 5BWiring XX134 07 00 Rev 908 SurveyorVFT Camera Dome System...