XX134-07-00 Rev 908 SurveyorVFT Camera Dome System
9BCompetitive Protocols
•
59
Philips
Function
Keypress
Function
Keypress
Use On-46-Enter shortcut to enter Dome menu.
Enter Menu
Use Focus Far button to select and save
options. Use Iris Close button to abort or leave
options. Move joystick up and down to select
and highlight Dome menu options (joystick
does not support "press and hold" navigation
and editing when in Dome menu). Use shortcut
Set-1021-ENTER for Aux 1, use Set-1022-
ENTER for Aux 2 and use Set-1023-ENTER for
Aux3. Note: In order for the shortcut to work, the
keypad must be unlocked. To unlock, use Off-
90-Enter unlock menu.
Set Transmit Polarity
Not Supported
Select/Store
Focus Far button
Program Sectors
Supported. Use Dome menu to enable sector
blanking. Use On-86-Enter to assign sectors
(use Set-1022-Enter for Aux 2 and use Set-1023-
Enter for Aux3).
Backup/Abort/Exit
Iris Close button
Reset Dome
Set-97-Enter
Iris Open
Iris Open
Set AP limits
To set Left limit use Set-101-Enter and to set
Right limit use Set-102-Enter.
Iris Close
Iris Close
Set Pan limits
Not Supported
Focus Near
Focus Near
Diagnostic Screen
Not Supported
Focus Far
Focus Far
Debug Screen
Not Supported
Zoom Out
Twist joystick CCW
Preset Tours
To save tours use either Set-80-Enter through
Set-87-Enter shortcuts or Dome menu. To recall
presets use Shot-80-Enter through Shot-87-
Enter shortcuts. All 7 tours are supported.
Zoom In
Twist joystick CW. To zoom in using digital
zoom turn joystick CW again after reaching the
end of analog zoom spectrum.
Auto Tour
Record auto tour 88 use On-100-Enter, Record
auto tour 89 use On-101-Enter, Playback 88 auto
tour On-51-Enter, Playback auto tour 89 On-53-
Enter, Continuous Playback auto tour 89 use On-
52-Enter and Continuous Playback auto tour 88
use On-50-Enter. Also, auto tours can be saved
using Dome menu.
Camera Off
Not Supported
Night Mode- Manual
Not Supported
Camera On
Not Supported
Alarms
If the user wants to use the alarms they must be
acknowledged from within the dome (auto
acknowledge).
Autopan
Use On-2-Enter shortcut. To set Autopan Left
and Right limits use Set-101-Enter and Set-102-
Enter shortcuts respectively.
Alarm Acknowledge
Auto acknowledge is only supported
Autoiris
Use On-3-Enter shortcut. Use Iris Open or Iris
Close buttons to switch back to manual iris
Flip (Turn 180 degrees)
N/A
Lens Speed
Not Supported
Camera Control
Including Adjust
V-Phase
N/A
Auxs
Not Supported
To call Factory Home Position use Set-110-
Enter. To save home position preset use Dome
menu.
Presets
To save presets use either Set-1-Enter through
Set-79-Enter shortcuts or Dome menu. To recall
presets use Shot-1-Enter to Shot-79-Enter
shortcuts. All 79 presets are supported.
Pan and Tilt Lockout
Not Supported
NOTE: Dome "PTZ timeout" menu feature is
not enabled due to Philips protocol PTZ
control delay limitation.
Содержание SVFT-C22
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 15: ...Unpacking the SurveyorVFT Outdoor Pendant XX134 07 00 Rev 908 SurveyorVFT Camera Dome System 3BIntroduction 7...
Страница 18: ...10 3BIntroduction XX134 07 00 Rev 908 SurveyorVFT Camera Dome System...
Страница 33: ...Figure 18 Outdoor Lower Dome Installation XX134 07 00 Rev 908 SurveyorVFT Camera Dome System 4BInstallation 25...
Страница 34: ...26 4BInstallation XX134 07 00 Rev 908 SurveyorVFT Camera Dome System NOTES...
Страница 36: ...Figure 19 Customer Interface Board Connections 28 5BWiring XX134 07 00 Rev 908 SurveyorVFT Camera Dome System...