XX134-07-00 Rev 908 SurveyorVFT Camera Dome System
Twisted-Pair Cable
CAUTION: Careful selection of the proper cable is essential to obtain the best performance from this
equipment. Vicon assumes no responsibility for poor performance when cables other than
those recommended are installed.
t
Ma erials
Use a pure copper stranded conductor with or without a tin plating to obtain a low DC resistance. Do not use cable with
ither a steel or an aluminum stranded conductor because these do not transfer signals effectively
e
p
for long distances. The
referred insulation and cable jacket is Polyvinyl chloride (PVC). It has better electrical characteristics than polyethylene
ir in a single jacket. This configuration is
the most convenient for RS-422/ RS485 applications. Single twisted pair is also a suitable cable.
Cho
distance for the most reliable digital control refers to the distance between the CPU/Keypad and the Camera Dome
Recommended Individually-Shielded, Twisted-Pair Cable Types
hree
of distances.
and resists flames, sunlight and most solvents, but is more vulnerable to moisture.
Cable Types
The most commonly used cable types are dual individually-shielded, twisted pa
ose a Belden cable type by referring to the characteristics and maximum distances listed below. The maximum
Assembly. The characteristics of the cables in Table 6 should be used as a guideline when cables other than Belden are
used. Materials and construction must follow the guidelines above.
Table
UTP Connection
For NVT models, where video is transmitted over twisted-pair cable, a UTP receiver is required. Vicon offers t
receivers to provide video transmission over a range
NVT Receiver
Wire Gauge
(AWG)
Category Type
Distance
ft (m)
V212-NVT
24-16
2, 3, 4, 5 or better
500 (152)
V213-NVT
24-16
2, 3, 4, 5 or better
1000 (304)
V6
24-16
2, 3, 4, 5 or better
3000 (915)*
52R-NVT
*Video signals traveling in opposite directions may co-exist in the same wire bundle up to 2000 ft (600 m) if Cat-5 wire is used.
Table
Oper
1.5-inch Pipe Design
ating Distances for UTP Installations
ation
The standard “1.5-inch pipe” referred to in this manual has actual dimensions of:
Outside diameter: 1.9 inches (48.3 mm).
Inside diameter: 1.61 inches (40.9 mm).
mm) minimum (ANSI “standard” grade thickness).
Wall thickness: 0.145 inches (3.37
CABLE
TYPE
WIRE SIZE
(AWG)
INSULATION
MATERIAL
JACKET
MATERIAL
DISTANCE ft (m)
max.
NUMBER OF
TWISTED PAIRS
Belden 9406
22
PVC
PVC
5000 (1500)
2
Belden 9402
20
PVC
PVC
5000 (1500)
2
Belden 8723
22
Polypropylene
PVC
8000 (2400)
2
lden 8162
Be
24
Datalene¹
PVC
15000 (4600)
2
Belden 9729
24
Datalene¹
PVC
15000 (4600)
2
e
1
B lden 9182
22
Datalene¹
PVC
25000 (7600)
¹
Datalene is a Registered Trademark of Belden. Belden Inc.
http://www.belden.com/
(800) 235-3361
Содержание SVFT-C22
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 15: ...Unpacking the SurveyorVFT Outdoor Pendant XX134 07 00 Rev 908 SurveyorVFT Camera Dome System 3BIntroduction 7...
Страница 18: ...10 3BIntroduction XX134 07 00 Rev 908 SurveyorVFT Camera Dome System...
Страница 33: ...Figure 18 Outdoor Lower Dome Installation XX134 07 00 Rev 908 SurveyorVFT Camera Dome System 4BInstallation 25...
Страница 34: ...26 4BInstallation XX134 07 00 Rev 908 SurveyorVFT Camera Dome System NOTES...
Страница 36: ...Figure 19 Customer Interface Board Connections 28 5BWiring XX134 07 00 Rev 908 SurveyorVFT Camera Dome System...