Set Default Call-Up
The default call-up specifies the condition of each monitor in the CCTV system when power is applied.
Menu Path: Main Menu
→
Video Switch Action
→
Set Default Call-Up
MONITOR DEFAULT CALLUP
x / -
/
ENTR/ESC
-
-
-
CYCLE CHOICE
CURSOR UP/DWN
STORE/ABORT
MONITOR NUMB.
ACTION
SELECT NUMB.
HOME RECALL
01
CAMERA
001
ENABLED
:
:
:
:
Monitor Number
Select a monitor and define the actions as described in the following section(s). Repeat for each monitor.
Settings:
01 to 64
Keys:
Numeric keypad’s + (plus) key or - (minus) key
Action
Upon system startup, monitors may be set to display no video (Blank), display the video from a specified
camera station (Camera), begin a tour (Tour), or display the video from the camera station as defined in a
salvo (Salvo).
Note: The Salvo action applies only to the monitor specified at the top of this screen.
Settings: Camera
Blank
Tour
Salvo
Keys:
Numeric keypad’s + (plus) key or - (minus) key
Default:
Blank
Select Number
If the Action setting is Blank, the Select Number and Home Recall settings will not display. For other settings,
select the number of the camera, tour, or salvo to be selected upon system startup.
Settings:
001 to 512 (When set for camera call up.)