XX190-10-XX Pilot Select
Alarm Actions
•
43
Enable Alarm Inputs
X-IA alarm inputs must be enabled in order to be processed. X-IA alarms may be enabled in groups referred
to as patterns. Three patterns are available. The use of patterns allows X-IA alarms to operate as a group.
For example, an Alarm Enable event using pattern A could be scheduled for daylight hours and pattern B
could be reserved for night.
Note: Use X-IA alarms rather than receiver alarms for critical surveillance areas.
Menu Path: Main Menu
→
Alarm Actions
→
Set Input Controls
→
Enable Alarm Inputs
ENABLE X-IA ALRM INPUTS
X-IA INPUT PATTERN :
B
x / -
- ENABLE/DISABLE
, , ,
- CURSOR CONTROL
ENTR/ESC - STORE/ABORT
000: ENABLED,
: DISABLED
006
012
018
024
005
011
017
023
004
010
016
022
003
009
015
021
001
007
013
019
002
008
014
020
004
010
016
022
X-IA Input Pattern
Select an X-IA input pattern and define which alarms will be enabled as discussed in the next section. Use the
Tab key to move the cursor from the X-IA Input Pattern setting to the group of input numbers.
Note: Upon power-up, the system will default to pattern A. When it is time for the next pattern to begin, the
system will follow the system programming.
Settings:
A, B, C
Keys:
Numeric keypad’s + (plus) key or - (minus) key
Default:
A
X-IA Alarm Inputs
Enable the X-IA alarms that will be part of the pattern shown in X-IA Input Pattern at the top of the screen.
The Tab key is used to move back up to the X-IA Input Pattern setting so that the next pattern may be
defined.
Settings: Enabled
Disabled
Keys:
Numeric keypad’s + (plus) key or - (minus) key
Shift and numeric keypad’s + (plus) or - (minus) key to set all alarms past cursor
Default:
Enabled
Содержание Pilot Select V1566