XX190-10-XX Pilot Select
Administration
•
13
Program Timed Events
Five timed event types are programmable in the software: Tours, Salvos, Presets, Alarm Enable, and Alarm
Type. The first three event types specify the method of video switching to be performed. Alarm enable and
alarm type events control which alarm patterns are enabled and which will operate as momentary.
Menu Path: Main Menu
→
Administration
→
Program Timed Events
/
x /-
ENTR/ESC
-
-
-
CURSOR UP/DWN
CYCLE CHOICE
STORE/ABORT
EVENT NUMBER
EVENT TYPE
PATTERN/NMBR
TIME OF DAY
SCHEDULE
DAY OF WEEK
01
ALRM TYP
A
00:00
ONCE
SUN
:
:
:
:
:
:
PROGRAM TIMED EVENTS
Event Number
The maximum number of timed events in the system is 64. This maximum does not apply to events which are
not timed. Any combination of events may be identified as timed events. For example, a configuration might
include 20 timed presets, 30 timed salvos, 4 timed tours, and 10 timed enabled alarms.
Settings:
01 to 64
Keys:
Numeric keypad’s + (plus) key or - (minus) key
Event Type
There are five timed event types available in the system. Tours, Salvos and Presets define video switching
functions. The Tour setting is used to select a video switching function defined as a series of preset video
displays from various camera stations on a specified monitor or on various monitors, depending upon the tour
type. The tour type may be monitor or salvo. A group of monitors displaying video from predefined camera
stations may be defined as a Salvo. The Preset setting specifies the pan, tilt, lens preset position and settings
to be recalled when the event is selected.
The Alarm Enable setting specifies the pattern of alarms to be enabled. This allows an event to be
programmed that automatically enables one pattern of alarms for daytime monitoring and a different pattern
for nighttime surveillance, for example. The Alarm Type setting specifies that a pattern of alarms, with each
alarm in the pattern set to operate as momentary or latching, will be scheduled as a timed event. Therefore, if
an alarm activates during this time period, it will act as momentary or latching. A separate timed event must
be scheduled to enable these alarms using the Alarm Enable setting.
Settings: Tour
Salvo
Preset
Alarm
Enable
Alarm
Type
Keys:
Numeric keypad’s + (plus) key or - (minus) key