26
•
Keypad/Receiver
XX190-10-XX Pilot Select
Communications Delay
The communications delay (COMM. DELAY) time is the length of time that the system will wait before
assuming that a receiver is off-line. This provides the delay time needed if a modem is connected to the
receiver jack.
Settings:
000 to 990 msec, in 10 msec increments
Keys:
Numeric keypad’s + (plus) key or - (minus) key
Default:
000 msec
Home Position
The home position is defined as preset 01 for all camera stations. If the home position is enabled, this feature
may be used to automatically direct the camera stations to preset position 01 when alarms are acknowledged
or on power-up.
Settings: Enabled
Disabled
Keys:
Numeric keypad’s + (plus) key or - (minus) key
Default:
Enabled
Home Aux 1
The Home Aux 1 setting defines the condition of aux 1 when the home position feature is activated (during
alarm acknowledgment or on power-up).
Settings:
N/C (not connected)
On
Off
Keys:
Numeric keypad’s + (plus) key or - (minus) key
Default:
N/C