42
•
Alarm Actions
XX190-10-XX Pilot Select
Set Aux 1 Controls
When an active receiver alarm has been acknowledged, the receiver may be preprogrammed to return to the
home position and to control AUX1.
The settings are On (which turns AUX1 on), Off (which turns AUX1 off), Restore (restores AUX 1 to its
prealarm state) and No Action (which leaves AUX 1 in the state defined in the Edit Alarm Call-Up screen.
Menu Path: Main Menu
→
Alarm Actions
→
Set Receiver Actions
→
Set Aux. 1 Controls
RCVR AUX. 1 ACK. ACTION
RCVR NO.
001
002
003
004
005
006
007
008
ACK. ACTION
ON
RESTORE
NO ACTION
OFF
OFF
OFF
OFF
OFF
ENTR/ESC - STORE/ABORT
Settings: On
Off
Restore
No
Action
Keys:
Numeric keypad’s + (plus) key or - (minus) key
Default:
No Action
Set Input Controls
The Set Input Controls Menus apply to X-IA alarms only. X-IA alarms are V1200X-IA and/or V1300X-IA alarm
interface devices connected directly to EXTERNALCONTROL IN/ALARM on the rear panel.
Menu Path: Main Menu
→
Alarm Actions
→
Set Input Controls
ALARM INPUT CONTROLS
1) ENABLE ALARM INPUTS
2) SET MOMENTARY INPUT
3) SET CLOSURE TYPE
ENTER SELECTION
ESC - PREVIOUS MENU